RPM Sensor Based Dynamic Notch Setup¶
Setup an RPM sensor.
Set INS_HNTCH_MODE and/or INS_HNTC2_MODE = 2 or 5 to use an RPM sensor to set the harmonic notch frequency.
Set INS_HNTCH_ENABLE and/or INS_HNTC2_ENABLE = 1 to enable the harmonic notch
Set INS_HNTCH_REF and/or INS_HNTC2_REF = 1 to set the harmonic notch reference value to unscaled, unless the RPM sensor is reporting a fraction of the actual rotor speed. This might occur in a geared drive train setup. If the reported RPM is 1/3 the actual, for example, set this to 0.33.
Set INS_HNTCH_FREQ and/or INS_HNTC2_FREQ = below the hover frequency. In the RPM based dynamic notch, this parameter sets the lower frequency limit of the notch. So even if the RPM sensor reads a lower value, the notch’s center frequency will remained constrainded to the value of this parameter. You can easily determine the hover frequency by performing a hover and looking at the RPM sensor log data (e.g. RPM.rpm1).
Set INS_HNTCH_BW and/or INS_HNTC2_BW = half of INS_HNTCH_FREQ
Checking Harmonic Notch Effectiveness¶
Check the performance of the filter(s) after setup by doing another post filter configuration test flight as discussed in the Measuring Vibration with IMU Batch Sampler or Raw IMU Logging for FFT Analysis page for this and analyze the logs.